-
prosto
Precision/Recall curve drawing.
- 2013-03-06 05:28:15下载
- 积分:1
-
light_preprocess
该代码是对人脸进行光照处理,先进行gamma变换,然后进行Dog双边滤波,然后进行灰度亮度的均衡。该方法能够有效提高光照变化的情况下的系统识别性能(The code is the human face of light treatment, the first for gamma conversion, and then Dog bilateral filtering, then the brightness of the gray balance. The method can effectively improve the illumination changes in the case of system identification performance)
- 2013-08-21 11:29:47下载
- 积分:1
-
MWC2.1
MWC2.1飞控 arduino代码设置(MWC2.1 flight control arduino code set)
- 2013-11-26 11:20:52下载
- 积分:1
-
SingleSidebandedModified
double side band modulation code
- 2015-01-31 07:32:04下载
- 积分:1
-
MATLAB6
详细介绍了Simulink工具箱,对于系统仿真很有用(Details the Simulink toolbox it is useful for system simulation)
- 2012-05-19 18:01:38下载
- 积分:1
-
IGSreadN
matlab编写的读取IGS广播星历文件(.n)文件的程序。读取完成后将数据分类储存为cell格式和struct格式。(Matlab prepared to read IGS broadcast ephemeris file (.N) file procedures. After reading is finished, the data is sorted into cell and struct format.)
- 2017-08-31 21:29:30下载
- 积分:1
-
Spectrum-analysis
自己做的频谱分析仪,含有GUI界面,希望对打击有帮助。(Spectrum analysis)
- 2013-05-06 16:42:27下载
- 积分:1
-
参考文献
利用matlab的gui设计的带有输入和输出功能的界面图形,可视性很强,自己独立编写的数据和图形,学习非常值得(Uses the Matlab GUI design to have the input and output function the interface graph, the visibility is very strong, the data and the graph which oneself compiles independently, the study is very worthwhile.)
- 2020-06-19 18:40:02下载
- 积分:1
-
S
说明: S 函数使用及应用举例,对涉及到simulink里s函数的应用有详细的解释(The use and application of S function, for example, relating to the simulink function in the application of s has a detailed explanation)
- 2008-07-24 12:18:47下载
- 积分:1
-
GND
接地技术最早是应用在强电系统(电力系统、输变电设备、电气设备)中,为了设备和人身的安全,将接地线直接接在大地上。由于大地的电容非常大,一般情况下可以将大地的电位视为零电位。后来,接地技术延伸应用到弱电系统中。对于电力电子设备将接地线直接接在大地上或者接在一个作为参考电位的导体上,当电流通过该参考电位时,不应产生电压降。然而由于不合理的接地,反而会引入了电磁干扰,比如共地线干扰、地环路干扰等,从而导致电力电子设备工作不正常。可见,接地技术是电力电子设备电磁兼容技术的重要内容之一,有必要对接地技术进行详细探讨。(Grounding technology was first applied in strong electric system (power system, power transmission equipment, electrical equipment), in order to equipment and personal safety, the ground wire directly connected to the earth. Because the earth capacitance is very large, under normal circumstances can be considered to be zero potential earth potential. Later, grounding techniques applied to extend the weak system. For power electronic devices directly connected to the ground wire on the ground or connected to a reference potential as a conductor, when the current through the reference potential, and should not generate voltage drop. However, due to unreasonable ground, but will the introduction of electromagnetic interference, such as co-ground interference, ground loop interference, resulting in power electronic equipment is not working properly. Visible, grounding technology is an important part of power electronic equipment EMC technology, it is necessary for grounding techniques disc)
- 2015-02-07 09:58:04下载
- 积分:1